Home | Products | E-mail : info@chandcompany.com
Tel. No. : +91 11 23213236, 23218581, 23216796

promotional offers

DIGITAL CALIPER

Resolution: 0.01mm/0.0005"
Model No.: 1112-150
Price : 1586
Model No.: 1112-200
Price : 2409
Model No.: 1112-300
Price : 4428

View
VERNIER CALIPER

Graduation:0.02mm/0.001
Model No.: 1205-1502
Price : 1185

View
DIAL CALIPER

Graduation: 0.01mm
Model No.: 1312-150A
Price : 2103
View

DIGITAL HEIGHT GAUGE

Resolution: 0.01mm/0.0005"
Model No.: 1150-300
Price : 11843

View
DIAL INDICATOR

Graduation:0.01mm
Model No.: 2301-10
Price : 1210

View
Dial Test Indicator

Graduation: 0.01mm
Model No.: 2380-08
Price : 2178

View
BORE GAUGE

Repeatability:0.003mm
Model No.:2322-35A
Price : 4913

Model No.:2322-60A
Price : 4914

Model No.:2322-160A
Price : 5101

View
MAGNETIC STAND

For digital/dial indicators and dial test indicators
Model No.: 6201-60
Price : 861

View

HOME > fluke > Accessoriest > FLUKE - CODE fluke-i2500

i2500-18 iFlex® Flexible Current Probes
Be ready for anything.
The Fluke iFlex flexible current probes expand the measurement range of the select Fluke meters to 2500 A ac while providing the ultimate measurement flexibility. The iFlex probes connect directly to the meter, displaying current measurements without error prone scaling factors. The 1.8 m (6 ft) cord allows separation between the measurement location and the clamp meter making it easier to view the display. The large loop size and thin cross section allow measurement of awkward sized conductors and improved wire access in crowded spaces. Available in 25 cm (10 in) and 45 cm (18 in) sizes.

Safety Conformance
IEC/EN 61010-1:2001, 1000V CAT III, 600V CAT IV
SR. Fluke CODE Price In Rs.
1 i2500-18 10,300


Specifications

i2500-18 and i2500-10

Range

Resolution

Accuracy

AC Current*

2500 A

0.1 A

3% ± 5 digits**

Frequency*

500 Hz

0.1 Hz

0.5% ± 5 digits

External magnetic
field rejection

(with cable >10 cm from the coupling)

40 dB

Inrush*

 •

Safety rating

CAT III 1000 V, CAT IV 600 V

*When used with compatible Fluke meter. Accuracy stated includes probe and meter accuracy.
** For position accuracy at non-optimum positions, see Position sensitivity specifications table “A

Position sensitivity specifications

Distance from optimum

i2500-10

i2500-18

Additional iFlex error

A

0.5 in (12.7 mm)

1.4 in (35.6 mm)

± 0.5%

B

0.8 in (20.3 mm)

2.0 in (50.8 mm)

± 1.0%

C

1.4 in (35.6 mm)

2.5 in (63.5 mm)

± 2.0%

Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature.

Top Brands

  • Insize
  • Toolface
  • Trumax
  • Apex
  • Arete
  • Truthread
  • Torque Master
  • Kann
  • Taco
  • Totem
  • Indian Tool
  • CP Grat-EX
  • Sewak
  • Giant
  • Bagson
  • Luthra